Provides the VACON® drive with an AS-i bus interface
Slots VACON® 100: CDE
Slots VACON® 20X: E
Provides a multiprotocol RS485 interface to VACON® NX products. The option board is identical to OPT-C8 apart from the fieldbus connector
Modbus RTU protocol support
Metasys N2 protocol support
Termination resistor can be activated with jumper
5-pin connector plug
Slots VACON® NXS/NXP: DE
Slots VACON® NXL: DE
Provides a PROFIBUS DP-V0 interface to VACON® NX products. The option board is identical to OPT-C5 apart from the fieldbus connector
PROFIBUS DP-V0 protocol support
Vacon profile and PROFIdrive-like profile
Termination resistor can be activated with jumper
5-pin connector plug
Slots VACON® NXS/NXP: DE
Slots VACON® NXL: DE
Provides a LonWorks interface to VACON® NX and VACON® 100 products
LonWorks protocol
3-pin plug connector
Slots VACON® NXS/NXP: DE
Slots VACON® NXL: DE
Slots VACON® 100: DE
Provides a PROFIBUS DP-V0 interface to VACON® NX products. The option board is identical to OPT-C3 apart from the fieldbus connector
PROFIBUS DP-V0 protocol support
VACON® profile and PROFIdrive-like profile
Termination resistor can be activated with jumper
Sub-D9 connector
Slots VACON® NXS/NXP: DE
Provides a CANopen interface to VACON® NX products
CANopen protocol support
VACON® profile and CiA 402-like profile
5-pin plug connector
Slots VACON® NXS/NXP: DE
Slots VACON® NXL: DE
A special version of the PROFIBUS options that emulates the VLT® 3000 commands in the VLT® AutomationDrive
The VLT® 3000 can be replaced by the VLT® AutomationDrive, or an existing system can be expanded without costly change of the PLC program
For upgrade to a different fieldbus, the installed converter is easily removed and replaced with a new option. This secures the investment without losing flexibility
Provides a multiprotocol RS-485 interface to VACON® NX products. The option board is identical to OPT-C2 apart from the fieldbus connector
Modbus RTU protocol support
Metasys N2 protocol support
Termination resistor can be activated with jumper
Sub-D9 connector
Slots VACON® NXS/NXP: DE
Slots VACON® NXL: DE
This option board provides ABB Selma 2 protocol interface to VACON® NXP products
Selma 2 protocol
4-pin plug connector
Slots VACON® NXP: DE
Provides Modbus TCP interface to VACON® NX products
Modbus TCP protocol
1x RJ45 connector
Slots VACON® NXS/NXP: DE
Slots VACON® NXL: DE
Provides BACnet MS/TP interface to VACON® NX products
BACnet MS/TP (RS485-based) protocol
5-pin plug connector
Slots NXS/NXP: DE
Slots NXL: DE
Provides a PROFINET interface to VACON® NX products
PFOFINET protocol
VACON® profile and PROFIdrive-like profile
1x RJ45 connector
Slots VACON® NXS/NXP: DE
Slots VACON® NXL: DE
Provides EtherNet/IP interface to VACON® NX products
EtherNet/IP protocol
VACON® profile and CIP AC Drive-like profile
1x RJ45 connector
Slots VACON® NXS/NXP: DE
Slots VACON® NXL: DE
Provides a PROFIBUS DP-V1 interface to VACON® 100 and VACON® 20 products. The option board is identical to OPT-E5 apart from the fieldbus connector
PROFIBUS DP-V1 protocol support
VACON® profile and PROFIdrive-like profile
5-pin plug connector
Slots VACON® 100: DE
Slots VACON® 20: E
Provides PROFIBUS DP-V1 interface to VACON® 100 and VACON® 20 products. The option board is identical to OPT-E3 apart from the fieldbus connector
PROFIBUS DP-V1 protocol support
VACON® profile and PROFIdrive-like profile
Sub-D9 connector
Slots VACON® 100: DE
Slots VACON® 20: E
This option board provides CANopen interface to VACON® 100 and VACON® 20 products
CANopen protocol support
VACON® profile and CiA 402-like profile
5-pin plug connector
Slots VACON® 100: DE
Slots VACON® 20: E
Provides DeviceNet interface to VACON® 100 and VACON® 20 products
DeviceNet protocol support
VACON® profile and CIP AC Drive-like profile
5-pin plug connector
Slots VACON® 100: DE
Slots VACON® 20: E
Provides multiprotocol Ethernet interface to VACON® NXS, VACON® NXP, VACON® 100 and VACON® 20 products
Modbus TCP and PROFINET protocol support
Future EtherNet/IP protocol support
2x RJ45 connectors with built-in switch
RSTP protocol support currently
Slots VACON® NXS/NXP: DE
Slots VACON® 100: DE
Slots VACON® 20: E
Provides EtherCAT interface to VACON® NXP, VACON® 100 and VACON® 20 products
EtherCAT protocol support
Based on BECKHOFF ASIC
VACON® profile and CiA 402-like profile
2x RJ45 connectors (EtherCAT supports line topology)
ts VACON® NXP: DE
Slots VACON® 100: DE
Slots VACON® 20: E
Limited availability
Provides the VACON® 100 product with the Safe Torque Off (STO) safety function. The option board also features an ATEX thermistor input for protection against motor over-temperature, where the motor is located in an ATEX environment. One relay output is also available for indicating STO function
Safe Torque Off (STO) up to SIL3 using two independent digital input channels
ATEX thermistor input
One relay output for STO function
Slot: E
Provides the VACON® NXP product with the Safe Torque Off (STO) safety function. The option board also features an ATEX thermistor input for protection against motor over-temperature, where the motor is located in an ATEX environment. 2 relay outputs are also available in the option board
Safe Torque Off (STO) up to SIL2, PL d, Cat. 3 using 2 independent digital input channels
ATEX thermistor input
1 NO relay output
1 NO/NC relay output
Slot: B
Provides a variety of input and output signals for controlling VACON® NXS and VACON® NXP drives
6 digital inputs, 24 V DC
1 open-collector digital output
2 analog inputs (0...10 V or -10…+10 V or 0…20 mA)
1 analog output (0…10 V or 0…20 mA)
+10 V DC reference
+24 V DC external supply or voltage output
Slot: A
Provides two relay output signals for VACON® NXS and VACON® NXP products
2 pcs NO/NC relay outputs
Slot: B
Provides 2 relay output signals and a thermistor input for over-temperature protection for VACON® NXS and VACON® NXP products
1 NO/NC relay output
1 NO relay output
1 PTC thermistor input
Slot: B
Used to connect VACON® NXP products to TTL- and TTL(R)-type pulse/incremental encoders conforming to the RS422 specification
Differential A+, A-, B+, B-, Z+ and Z- signals
1 qualifier input, used to trace the Z-pulse
1 fast digital input, used to trace very short pulses
Selectable encoder voltage supply +5/+15/+24 V
Slot: C
Used to connect VACON® NXP products to HTL-type pulse/incremental encoders
Differential A+, A-, B+, B-, Z+ and Z- signals
1 qualifier input, used to trace the Z-pulse
1 fast digital input, used to trace very short pulses
Selectable encoder voltage supply +5/+15/+24 V
Slot: C
Used to connect 2 HTL-type pulse/incremental encoders to a VACON® NXP product
Differential A+, A-, B+, B-, Z+ and Z- signals
1 qualifier input, used to trace the Z-pulse
1 fast digital input, used to trace very short pulses
Selectable encoder voltage supply +15/+24 V
Slot: C
Provides a variety of input and output signals for controlling VACON® NXS and VACON® NXP drives. It is equivalent to OPT-A1 except that analog inputs and outputs are galvanically isolated in OPT-A8
6 digital inputs, 24 V DC
1 open-collector digital output
2 analog inputs (0...10V or -10…+10V or 0…20 mA)
1 analog output (0…10V or 0…20 mA)
+10 V DC reference
+24 V DC external supply or voltage output
Slot: A
Provides a variety of input and output signals for controlling VACON® NXS and VACON® NXP drives. It is equivalent to OPT-A1 except that in OPT-A9 the connectors have a cross-section of 2.5 mm2
6 digital inputs, 24 V DC
1 open-collector digital output
2 analog inputs (0...10V or -10…+10V or 0…20 mA)
1 analog output (0…10V or 0…20 mA)
+10 V DC reference
+24 V DC external supply or voltage output
Slot: A
Provides a variety of input and output signals for controlling VACON® NXL drives
3 digital inputs, 24 V DC
1 open-collector digital output
1 NO relay output
+24 V DC external supply or voltage output
Slot: E
Used to connect HTL-type pulse/incremental encoders to VACON® NXP products
The option board also outputs an Encoder Direction Signal and an Encoder Pulse Output Signal, which is produced by dividing the input pulses from the encoder.
Differential A+, A-, B+, B-, Z+ and Z- signals
1 digital output for encoder direction
1 digital output for encoder output, a programmable divider
Selectable encoder voltage supply +15/+24 V
Slot: E
Provides a variety of input and output signals for controlling VACON® NXL drives
3 digital inputs, 24 V DC
1 PTC thermistor input
1 NO relay output
+24 V DC external supply or voltage output
Slot: E
Used to connect sine-/cosine-type incremental encoders to a VACON® NXP product
Differential SIN+, SIN-, COS+, COS-, R+ and R- signals (1 volt peak-to-peak)
Selectable encoder voltage supply +5/+15/+24V
Slot: C
Provides a variety of input and output signals for controlling VACON® NXS and VACON® NXP drives
6 digital inputs, 42…240 V AC
1 open-collector digital output
1 analog input 0…10V
1 analog input -10…+10V
1 analog output 0…10V
1 analog output 0…20 mA
+15 V DC voltage output
+24 V DC external supply or voltage output
Slot: A
Provides a variety of input and output signals for controlling VACON® NXP drives
6 galvanically isolated digital inputs, 24 V DC
2 analog inputs (0...10V or -10…+10V or 0…20 mA)
2 analog outputs (0...10V or -10…+10V or 0…20 mA)
+10 V DC and -10 V DC reference
+24 V DC external supply or voltage output
Slot: A
Provides additional digital input and/or digital output signals to VACON® drives. Can be used in VACON® NX products and also in VACON® 100 and VACON® 20 product series
6 configurable digital input/output signals
0…24 V DC when configured as input
Open-collector when configured as output
Signal type is selected using jumpers
+24 V DC voltage output
Slots VACON®NXS/NXP: BCDE
Slots VACON®NXL: E
Slots VACON® 100: CDE
Slots VACON® 20: E
Provides additional relay output signals and a thermistor input to VACON® drives. Can be used in VACON® NX products and also in VACON® 100 and VACON® 20 product series
1 NO relay output
1 NO/NC relay output
1 PTC thermistor input
Slots VACON® NXS/NXP: BCDE
Slots VACON® NXL: E
Slots VACON® 100: CDE
Slots VACON® 20: E
Provides one analog input and two analog output signals to VACON® drives. Can be used in VACON® NX products and also in VACON® 100 and VACON® 20 product series
1 galvanically isolated analog input (0…20 mA)
2 galvanically isolated analog outputs (0…20 mA)
+24 V DC voltage output
Slots VACON® NXS/NXP: BCDE
Slots VACON® NXL: E
Slots VACON® 100: CDE
Slots VACON® 20: E
Provides three additional relay output signals to VACON® drives. Can be used in VACON® NX products and also in VACON® 100 and VACON® 20 product series
3 NO relay outputs
Slots VACON® NXS/NXP: BCDE
Slots VACON® NXL: E
Slots VACON® 100: CDE
Slots VACON® 20: E
Provides three temperature measurement channels to VACON® NXS and VACON® NXP drives
2 PT100 sensor inputs (3-wire)
Measurement channel #3 allows 1-3 sensors in series
-30…+200°C measurement range
For new installations, option OPT-BH is recommended
Slots VACON® NXS/NXP:BCDE
Provides five high-voltage digital inputs and one relay output to VACON® drives. Can be used in VACON® NX products and also in VACON® 100 and VACON® 20 product series
5 digital inputs, 42…240 V AC
1 NO relay output
Slots VACON® NXS/NXP: BCDE
Slots VACON® NXL: E
Slots VACON® 100: CDE
Slots VACON® 20: E
Enables speed feedback to a VACON® NXP drive from an EnDat 2 encoder. Use the EnDat interface to read the absolute position of the shaft. The option board outputs a simulated pulse encoder signal according to RS422 specification
Closed-loop control of the motor requires that sin/cos signals are available
Absolute encoder with Endat 2 protocol
Differential DATA, CLOCK, and sin/cos (1 Vpp) input
Selectable encoder voltage supply +5/+12/+15 V
2 Fast digital inputs for tracing short pulses
Output A+, A-, B+ and B- incremental signals according to RS422 specification
Slot: C
Enables speed feedback to a VACON® NXP drive from a resolver. The board provides a simulated pulse encoder output
Configurable excitation signal frequency, 2-20 kHz
Differential sin/cos feedback signals
Differential HTL freeze input for marking position data
Differential HTL encoder input (A, B and Z signals)
Differential HTL simulated encoder output (A, B and Z signals)
Slot: C
Enables speed feedback to a VACON® NXP product from an EnDat 2.1 encoder. Use the EnDat interface to read the absolute position of the shaft
Closed loop control of the motor requires that sin/cos signals are available.
EnDat 2.1 protocol support
DATA+, DATA-, CLOCK+ and CLOCK- differential signals
Differential SIN+, SIN-, COS+ and COS- signals (1 volt peak-to-peak)
Selectable encoder voltage supply +5/+12/+15 V
Slot: C
Provides additional output signals to VACON® drives. Can be used in VACON® 100 and VACON® 20 product series
1 open-collector digital output
1 analog output (0…10V or 0…20 mA)
1 NO relay output
Slots VACON® 100: CDE
Slots VACON® 20: E
Provides three temperature measurement channels to VACON® drives. Can be used in VACON® NXS, VACON® NXP and in VACON® 100 products
3 temperature measurement channels
PT100, PT1000, Ni1000, KTY84 sensor support
-50…+200°C measurement range
All measurement channels support 1…3 PT100 sensors in series
Slots VACON® NXS/P: BCDE
Slots VACON® 100: CDE
Allows VACON® NXP drives to be connected via fiber-optic cables. The link can be used for drive-to-drive communication or for paralleling of drives to achieve higher power
2x fiber-optic pairs
Slots VACON® NXP: DE
Enables connection of VACON® NXP drives via fiber-optic cables. Use the link for drive-to-drive communication or for paralleling of drives to achieve higher power. The board also includes a CAN interface for monitoring of multiple drives, for customized CAN communication or for I/O expansion
1 fiber-optic pair
Galvanically isolated CAN interface (3-pin plug connector)
IEC 61131 application CAN
MonitorBus
Slots VACON® NXP: DE
Enables connection of VACON® NXS and VACON® NXP drives to a PC via RS232 link
Galvanically isolated RS232 interface
D9 connector
Slots VACON® NXS/NXP: DE
Supplies a CAN interface to the IEC 61131 application of VACON® NXP drives. Use the CAN interface for monitoring of multiple drives, for customized CAN communication or for I/O expansion
Galvanically isolated CAN interface (3-pin plug connector)
IEC 61131 application CAN
MonitorBus
Slots VACON® NXP: DE
Provides VACON® NXP drives with an interface for measuring mains/line voltage. The board includes a transformer to reduce the line voltage to a measurable amplitude. The board is used in applications such as AFE, renewable energy or micro-grid
Line voltage and frequency measurement
External voltage transformer 1:60
380…690 V AC input voltage
Slots VACON® NXP: C
Provides relay outputs to the VACON® 100 HVAC products using old control cards
Compatible with 70CVB01015 and 70CVB01418 control cards
2 NO/NC relay outputs
1 NO relay output
Provides relay outputs and a thermistor input to the VACON® 100 HVAC products using old control cards
Compatible with 70CVB01015 and 70CVB01418 control cards
2 NO/NC relay outputs
1 PTC thermistor input
Provides a variety of input/output signals and an RS485 interface to the VACON® 100 and VACON® 100 FLOW products. Also VACON® 100 HVAC products with new control board support this I/O board
Compatible with 70CVB01582 control card
6 pcs 0…24V digital inputs
2 analog inputs (0…10V or 0…20 mA)
1 analog output (0…10V or 0…20 mA)
2 NO/NC relay outputs
1 NO relay output
+10 V DC output reference voltage
+24 V DC external supply or voltage output
RS485 interface for fieldbus
Provides a variety of input/output signals and an RS485 interface to the VACON® 100 and VACON® 100 FLOW products. VACON® 100 HVAC products with new control board also support this I/O board
Compatible with 70CVB01582 control card
6 digital inputs, 0…24 V
2 analog inputs (0…10 V or 0…20 mA)
1 analog output (0…10 V or 0…20 mA)
2 NO/NC relay outputs
1 PTC thermistor input
+10 V DC output reference voltage
+24 V DC external supply or voltage output
RS485 interface for fieldbus
40 kW cooling capacity
All models with stainless steel piping
1-pump model
Variations available in IP54 Rittal and Veda cabinets and without a cabinet
HXL-M-040-N-S: IP00
HXL-V-040-N-S: IP54, Veda cabinet
HXL-R-040-N-S: IP54 Rittal cabinet
Power range:
380 – 440 V AC
Cooling power:
0 – 40 kW
Flow:
40 – 120 l/min
120 kW cooling capacity
All models with stainless steel piping
1-pump model
2-pump models for marine applications
Variations available in IP54 Rittal and Veda cabinets and without a cabinet:
HXL-M-120-N-S: IP00, 1-pump
HXM-M-120-N-S: IP00, 2-pumps
HXL-R-120-N-S: IP54, Rittal cabinet, 1-pump
HXM-R-120-N-S: IP54, Rittal cabinet, stainless steel piping, 2-pumps
HXL-V-120-N-S: IP54, Veda cabinet, stainless steel piping, 1-pump
HXM-V-120-N-S: IP54, Veda cabinet, stainless steel piping, 2-pumps
Power range:
380 – 440 V AC
Cooling power:
0 – 120 kW
Flow:
120 – 360 l/min
300 kW cooling capacity
All models with stainless steel piping
1-pump model
2-pump models for marine applications
Several variations:
HXL-M-300-N-S: IP00, 1-pump
HXM-M-300-N-S: IP00, 2-pumps
HXL-R-300-N-S: IP54, Rittal cabinet, 1-pump
HXM-R-300-N-S: IP54, Rittal cabinet, 2-pumps
Power range:
380 – 440 V AC
Cooling power:
0 – 300 kW
Flow:
360 – 900 l/min
Liquid-to-air heat exchangers with cooling compressor
Manufactured by Lauda Ultracool
IP54 cabinet
Several models for different cooling capacity and coolant flow
Power range:
400 – 440 V AC/50 Hz
440 – 480 V AC/60 Hz
Flow:
UC-0030SP: 3.8 kW @ 35C/3.3 kW @ 45C – coolant flow 20 l/min
UC-0080SP: 13.7 kW @ 35C /11.2 kW @ 45C – coolant flow 40 l/min
UC-0140SP: 22.1 kW @ 35C /18.3 kW @ 45C – coolant flow 80 l/min
UC-0240SP: 41.8 kW @ 35C /34.2 kW @ 45C – coolant flow 120 l/min
UC-0400SP: 48.6 kW @ 35C /- – coolant flow 120 l/min
UC-0800SP: 97.2 kW @ 35C /- – coolant flow 240 l/min
UC-0500SP-E: -/43 kW @ 45C – coolant flow 120 l/min
UC-0500SP-E: -/86 kW @ 45C – coolant flow 240 l/min